Sign In | Join Free | My xpshou.com
China Hunan Zhengzhong Pharmaceutical Machinery Co., Ltd logo
Hunan Zhengzhong Pharmaceutical Machinery Co., Ltd
Focus on quality and create classics
Active Member

3 Years

Home > Ampoule Leak Testing Machine >

Electronical Ampoule Leak Testing Machine Micropore Leak Inspector

Hunan Zhengzhong Pharmaceutical Machinery Co., Ltd
Contact Now

Electronical Ampoule Leak Testing Machine Micropore Leak Inspector

Brand Name : Z-Zone

Model Number : AJL500

Certification : GMP ISO

Place of Origin : China

MOQ : 1 set

Price : USD 20,000-10,0000

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 20sets per month

Delivery Time : 60days

Packaging Details : Wooden packing

Application : 1-20ml

Capacity : 450-500 bottles/min

Power : 2.4kW,380V50Hz

Power range : 10kV~35 kV

Weight : about 1000kg

Dimension : 3694mm×1180mm×1364mm(L×W×H)

Contact Now

AJL500 Ampoule Injection Electronical Micropore Leak Inspector

Application

The machine is dedicated to inspect Ampoule, vial and oral liquid products for possible liquid leakage. It can inspect pinhole and cracks on those bottles.

Parameters

Application 1-20ml Ampoule, vial and oral liquid products
Capacity AJL300 300-400 bottles/min
Power 2.4kW,380, V50Hz
Output power range 10kV~35 kV
Output frequency range 500Hz~50kHz
Power channel numbers multi-channel high frequency high voltage power
Weight about 1000kg
Dimension 3694mm×1180mm×1364mm(L×W×H)

Working principle

Infeed conveyer belt takes inspected containers to infeed wheel for equidistant separation. Feed track takes container to deliver screw , then turn it over 90°to level to reach different inspection station. Inspection consists of many stations, it can inspect different position according to customer requirement and finally separate qualified and unqualified products automatically by the reject unit.

Voltage principle

V is high frequency high voltage power, its two ends is separately connected with emitting electrode and receiving electrode. C1 and C2 are capacitance between electrode and solution (Because of the cut off by isolated bottle surface, electrode can not contact solution, then form capacitance). R is solution resistance. When no leak present on container, the generated induction current is defined as I1. When container is leaked, the capacitance between bottle surface and electrode will disappear, capacitive reactance generated by capacitance is zero, the return circuit will generate higher current I2. Compare the current value to judge if the container is leaked.

Electronical Ampoule Leak Testing Machine Micropore Leak Inspector


Product Tags:

Electronical Ampoule Leak Testing Machine

      

Ampoule Leak Testing Machine Micropore

      
China Electronical Ampoule Leak Testing Machine Micropore Leak Inspector wholesale

Electronical Ampoule Leak Testing Machine Micropore Leak Inspector Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hunan Zhengzhong Pharmaceutical Machinery Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)